Call for Papers : Volume 15, Issue 05, May 2024, Open Access; Impact Factor; Peer Reviewed Journal; Fast Publication

Natural   Natural   Natural   Natural   Natural  

Performance analysis of a regenerative gas turbine plant modeled with vapour absorption refrigeration system

×

Error message

  • Deprecated function: Function create_function() is deprecated in include() (line 1 of /home4/vibu/public_html/journalajst.com/sites/all/modules/views/theme/views-view.tpl.php).
  • Deprecated function: Function create_function() is deprecated in include_once() (line 2 of /home4/vibu/public_html/journalajst.com/sites/all/themes/bootstrap/templates/system/textfield.func.php).
  • Deprecated function: Function create_function() is deprecated in include_once() (line 3 of /home4/vibu/public_html/journalajst.com/sites/all/themes/bootstrap/templates/system/textfield.func.php).
  • Deprecated function: Function create_function() is deprecated in include_once() (line 1 of /home4/vibu/public_html/journalajst.com/sites/all/themes/bootstrap/templates/system/form-element-label.func.php).
  • Deprecated function: Function create_function() is deprecated in include_once() (line 1 of /home4/vibu/public_html/journalajst.com/sites/all/themes/bootstrap/templates/system/container.func.php).
  • Deprecated function: Function create_function() is deprecated in include() (line 1 of /home4/vibu/public_html/journalajst.com/sites/all/modules/views/theme/views-view.tpl.php).
  • Deprecated function: Function create_function() is deprecated in include() (line 1 of /home4/vibu/public_html/journalajst.com/sites/all/modules/views/theme/views-view.tpl.php).
  • Deprecated function: implode(): Passing glue string after array is deprecated. Swap the parameters in drupal_get_feeds() (line 394 of /home4/vibu/public_html/journalajst.com/includes/common.inc).
  • Deprecated function: Function create_function() is deprecated in include_once() (line 1 of /home4/vibu/public_html/journalajst.com/sites/all/themes/bootstrap/templates/system/link.vars.php).
  • Deprecated function: Function create_function() is deprecated in include_once() (line 1 of /home4/vibu/public_html/journalajst.com/sites/all/themes/bootstrap/templates/system/breadcrumb.vars.php).
  • Deprecated function: Function create_function() is deprecated in include_once() (line 1 of /home4/vibu/public_html/journalajst.com/sites/all/themes/bootstrap/templates/system/status-messages.func.php).

One of the predominant factors that affect the performance of a gas turbine is the ambient temperature. This is basically because the power output of the gas turbine depends largely on the air mass flow through it. Therefore cooling the inlet air to the compressor increases the power output and overall efficiency of the plant by taking advantage of the GT higher mass flow rate when the temperature of the air entering the compressor decreases. In this work, the effects of vapour absorption refrigeration system on the performance of a GT plant were investigated. The results showed that a decrease of 2.97oC in ambient temperature from 25oC to 22.03oC at a peak turbine inlet temperature of 800K led to a gain in thermal efficiency of 0.7%, 2.443kJ/kg network output and 0.021kg/KWh drop in specific fuel consumption. The research showed that gas turbine plants perform better in temperate regions than in tropics. Therefore, retrofitting an air cooler that will restore the compressor inlet temperature to the design condition is imperative.

Author: 
Robert Poku and Tokoni W. Oyinki