UGC APPROVED JOURNAL

     

CATEGORIES

CERTIFICATE

COPYRIGHT AGREEMENT

 

Browse by Subject

  • Agricultural Sciences
  • Biology and Life Sciences
  • Chemistry & Chemical Engineering
  • Medicine, Health & Food
  • Physics
  • Materials Science
  • Mathematics & Statistics
  • Electrical & Computer Science
  • Earth, Energy & Environment
  • Architecture & Civil Engineering
  • Transportation & Logistics
  • Engineering & Technology
  • Economics & Management
  • Education
  • Social Sciences & Psychology
  • Arts, Literature & Linguistics

 

Bioinspired algorithm for the control of cardiac pacemaker

  • strict warning: Non-static method view::load() should not be called statically in /home4/vibu/public_html/journalajst.com/sites/all/modules/views/views.module on line 906.
  • strict warning: Declaration of views_handler_filter::options_validate() should be compatible with views_handler::options_validate($form, &$form_state) in /home4/vibu/public_html/journalajst.com/sites/all/modules/views/handlers/views_handler_filter.inc on line 607.
  • strict warning: Declaration of views_handler_filter::options_submit() should be compatible with views_handler::options_submit($form, &$form_state) in /home4/vibu/public_html/journalajst.com/sites/all/modules/views/handlers/views_handler_filter.inc on line 607.
  • strict warning: Declaration of views_handler_filter_boolean_operator::value_validate() should be compatible with views_handler_filter::value_validate($form, &$form_state) in /home4/vibu/public_html/journalajst.com/sites/all/modules/views/handlers/views_handler_filter_boolean_operator.inc on line 159.
  • strict warning: Declaration of views_plugin_row::options_validate() should be compatible with views_plugin::options_validate(&$form, &$form_state) in /home4/vibu/public_html/journalajst.com/sites/all/modules/views/plugins/views_plugin_row.inc on line 134.
  • strict warning: Declaration of views_plugin_row::options_submit() should be compatible with views_plugin::options_submit(&$form, &$form_state) in /home4/vibu/public_html/journalajst.com/sites/all/modules/views/plugins/views_plugin_row.inc on line 134.
  • strict warning: Non-static method view::load() should not be called statically in /home4/vibu/public_html/journalajst.com/sites/all/modules/views/views.module on line 906.
  • strict warning: Declaration of views_plugin_style_default::options() should be compatible with views_object::options() in /home4/vibu/public_html/journalajst.com/sites/all/modules/views/plugins/views_plugin_style_default.inc on line 24.
  • strict warning: Non-static method view::load() should not be called statically in /home4/vibu/public_html/journalajst.com/sites/all/modules/views/views.module on line 906.
  • strict warning: Non-static method view::load() should not be called statically in /home4/vibu/public_html/journalajst.com/sites/all/modules/views/views.module on line 906.
  • strict warning: Declaration of views_handler_argument::init() should be compatible with views_handler::init(&$view, $options) in /home4/vibu/public_html/journalajst.com/sites/all/modules/views/handlers/views_handler_argument.inc on line 744.
Author: 
Jeyanth Fedal Castro, V and Malathi, R
Abstract: 

Designing the controller for the control of cardiac pacemakers to maintain the heart rate in a efficient way is very challenging. Proportional - Integral - Derivative control schemes continue to provide the simplest and effective solutions to most of the control engineering applications today. However, tuning of these controllers is time consuming, not easy and generally lead to poor performance especially with non-linear systems. This paper presents a Bioinspired optimization (BIO) algorithm for tuning the (PID) controller parameters for the control of pacemaker. This approach has superior features, including easy implementation, stable convergence characteristic and good computational efficiency over the conventional methods. The PID conventional controller had been applied and results were compared with the automatic tuning BIO-PID for the pacemaker using Matlab coding .The proposed algorithm is used to tune the PID parameters and its performance has been compared with the conventional Ziegler Nichols method. The results obtained reflects that use of heuristic algorithm based controller improves the performance of pacemaker in terms of time domain specifications, set point tracking and regulatory changes and also provides an optimum stability. This paper discusses in detail, the Bioinspired technique and its implementation with PID tuning for a controller of a pacemaker. Compared to other conventional PID tuning methods, the result shows that better performance can be achieved with the soft computing based tuning method. The ability of the designed controller in terms, of tracking set point is also compared and simulation results are discussed.

EDITOR-IN-CHIEF

 

               Prof. Dr. ISMAIL YILDIRIM

CALL FOR PAPERS

CURRENT ISSUE

 

IMPACT FACTOR CERTIFICATE